ansible/test/integration/targets/vmware_vcenter_settings/tasks/main.yml
2018-12-10 11:01:15 +05:30

124 lines
3.2 KiB
YAML

# Test code for the vmware_vcenter_settings module.
# Copyright: (c) 2018, Christian Kotte <christian.kotte@gmx.de>
# GNU General Public License v3.0+ (see COPYING or https://www.gnu.org/licenses/gpl-3.0.txt)
- name: store the vcenter container ip
set_fact:
vcsim: "{{ lookup('env', 'vcenter_host') }}"
- debug: var=vcsim
- name: Wait for Flask controller to come up online
wait_for:
host: "{{ vcsim }}"
port: 5000
state: started
- name: kill vcsim
uri:
url: http://{{ vcsim }}:5000/killall
- name: start vcsim
uri:
url: http://{{ vcsim }}:5000/spawn?cluster=2
register: vcsim_instance
- debug:
var: vcsim_instance
- name: Wait for vcsim server to come up online
wait_for:
host: "{{ vcsim }}"
port: 443
state: started
- name: get datacenter
uri:
url: http://{{ vcsim }}:5000/govc_find?filter=DC
register: datacenters
- name: get a datacenter
set_fact:
dc1: "{{ datacenters.json[0] | basename }}"
- name: Configure general settings in check mode
vmware_vcenter_settings:
hostname: "{{ vcsim }}"
username: "{{ vcsim_instance.json.username }}"
password: "{{ vcsim_instance.json.password }}"
database:
max_connections: 50
task_cleanup: true
task_retention: 180
event_cleanup: true
event_retention: 180
runtime_settings:
unique_id: 7
managed_address: 192.168.1.0
vcenter_server_name: "{{ inventory_hostname }}"
user_directory:
timeout: 120
query_limit: true
query_limit_size: 100000
validation: true
validation_period: 1440
mail:
server: mail.example.local
sender: vcenter@{{ inventory_hostname }}
snmp_receivers:
snmp_receiver_1_url: localhost
snmp_receiver_1_enabled: true
snmp_receiver_1_port: 162
snmp_receiver_1_community: public
timeout_settings:
normal_operations: 30
long_operations: 120
logging_options: info
validate_certs: no
register: all_settings_results_check_mode
check_mode: yes
- debug: msg="{{ all_settings_results_check_mode }}"
- name: ensure general settings were configured
assert:
that:
- all_settings_results_check_mode.changed
- name: Configure general settings
vmware_vcenter_settings:
hostname: "{{ vcsim }}"
username: "{{ vcsim_instance.json.username }}"
password: "{{ vcsim_instance.json.password }}"
database:
max_connections: 50
task_cleanup: true
task_retention: 180
event_cleanup: true
event_retention: 180
runtime_settings:
unique_id: 7
managed_address: 192.168.1.0
vcenter_server_name: "{{ inventory_hostname }}"
user_directory:
timeout: 120
query_limit: true
query_limit_size: 100000
validation: true
validation_period: 1440
mail:
server: mail.example.local
sender: vcenter@{{ inventory_hostname }}
snmp_receivers:
snmp_receiver_1_url: localhost
snmp_receiver_1_enabled: true
snmp_receiver_1_port: 162
snmp_receiver_1_community: public
timeout_settings:
normal_operations: 30
long_operations: 120
logging_options: info
validate_certs: no
register: all_settings_results
- debug: msg="{{ all_settings_results }}"